SCHWING Boom Inspection Process
In order to conform to the strict standards required by ASME (American Society of Mechanical Engineers) and to separate from companies and individuals who falsely claim to be able to perform SCHWING Boom Inspections, SCHWING America Inc (SAI) has recently made changes to our requirements that dictate if a Boom Inspection is considered “SCHWING Approved” or inspected to OEM standards.
Boom Inspections performed on SCHWING equipment will no longer be based on if an individual is considered “SCHWING Certified” to perform inspections. Instead, the inspection itself shall be considered “SCHWING Approved” if all necessary criteria has been met, which is listed below:
- The inspector must have attended a SCHWING Boom Inspection seminars since 2022
- Current revision of the Structural and Operational Periodic Inspection reports must be used (click here for links to each form).
- Inspection reports must be sent in to boomrepair@SCHWING.com within 30 days of completion and be Certified Approved by SAI
- Repair Request Form 30007009 must be filled out and the appropriate pictures sent to boomrepair@SCHWING.com for all structural non-conformances.
- Upon completion and submittal of an inspection, the SCHWING Quality Department will review if the above criteria has been met and determine if any areas on the report must be re-inspected or changed.
SCHWING ONLY takes liability of any failed componentry if the above criteria is met approved.
NOTE* Even if a report is approved, SCHWING will not be liable for anything missing/not reported in an inspection. Examples of this include if a trained inspector fails to report a structural issue, is not thorough enough in the report, or pencil whips the report.
If the SCHWING Quality Department approves the report, SCHWING will issue a completed Boom Inspection sticker that shall be placed onto the machine that was inspected. This inspection sticker is marked with Rev. 2. Any SCHWING stickers applied that do not have this revision are no longer recognized by SAI
For questions about this process, please contact boomrepair@schwing.com or call 651-653-5438.
Insist on a SCHWING Trained Boom Inspector!
Not all independent inspectors are SCHWING trained. Call our service department today for a list of SCHWING trained inspectors.
Periodic inspections according to ASME standard B30.27-2009 include complete visual inspection of all structural areas, including:
• Booms (all sections)
• Pedestal (tower)
• Outriggers
• Main column and turret
• Hydraulic cylinders, lines and tubing, holding valves
• Safety decals
• Boom rests, steps, boom guide brackets, etc.
• Pin and bearing clearances
As per manufacturer standards, complete inspection of the material placing boom and structural support system shall be performed by a qualified person at the intervals listed below:
• First 5 years: every 1,000 working hours, or at least once per year (whichever occurs first)
• 5 to 10 years: every 500 working hours, or at least once per year (whichever occurs first)
• 10 years and older: every 250 working hours, or at least once per year (whichever occurs first)
SCHWING Structural and Operational Inspectors
To Schedule a Boom Inspection with a SCHWING Boom Inspector, click here.
SCHWING BOOM INSPECTORS
| Rupert Alanis Houston, TX | Will Ayers Winter Haven, FL | Zach White Saint Paul, MN |
|---|
SCHWING Trained Structural and Operational Inspectors
Concrete Pump Repair
a SCHWING company
mnewman@schwing.com
Mike Newman
White Bear Lake, MN
651-674-448
BAIR LLC
bair.inspections@yahoo.com
Basem Atih
Baltimore MD
443-966-0066
Bavery Building LLC
baverybuilding@gmail.com
Bart Bavery
Belleville, WI
608-516-3500
California Concrete Pump Sales And Service
info@caconcretepumpsales.com
Tyler Todd
Applegate, CA
530-210-2935
Certified Boom Inspection LLC
tusher@cbinspection.com
Todd Usher
Scranton, PA
612-802-6678
Craig's Welding LLC
craiglombard611@gmail.com
Craig Lombard
Whitelaw, WI
608-498-0217
Extreme Pumping
Tannergipson@extremepumpingllc.com
Tanner Gibson
Schertz, TX
210-360-9921
Fernandez Boom Inspection
fbi.rudell@yahoo.com
Rudell Fernandez & Rudy Fernandez
Arlington, TX
1-817-948-3772
Frontline Boom LLC
masonrockwellsmith@gmail.com
Mason Smith
Kalispell, MT
406-249-9824
Klein Welding Services
kleinkws@yahoo.com
Adam Klein
Denver, CO
720-270-9416
Lavallee Welding
lavalleewelding@yahoo.com
Cory Lavallee
Murrieta, CA
760-855-5146
Matec Consultants LTD.
steven@matec.ca
Steven Severson
Burnaby, BC
604-499-7934
Merli Concrete Pumping
pagraf03@yahoo.com
Patrick Graf
Gardena, CA
714-869-9486
Quality Concrete Pumps
qualityconcretepumpsllc@gmail.com
Joseph Bynum
Palm City, FL
772-263-9337
US Boom Inspection
robert@usboominspection.com
Robert Walker
Des Moines, IA.
515-639-1071
Wild Cat Welding Boom Inspection & Repair
wildcatwelding7757@gmail.com
Daniel Mestas
Eaton, CO
307-251-0330 or 970-454-8801
SCHWING Trained Boom Structural Inspectors
BAIR LLC
bair.inspections@yahoo.com
Omar Shamsi
Tampa, FL
443-966-0066
Concrete & Materials Placement
Brandon Richmond
brichmond@cmppumping.com
Charlotte, NC
919-830-5816
DL Inspection Services
David Luey
dave@dlinspection.ca
Hamilton, ON
905-869-9448
Olson Company
William Dyer
wldyer8@gmail.com
Dallas, TX
817-629-8005
Olson Company
Harley Daniel Koon
danielkoon87@gmail.com
Dallas, TX
817-941-3819
Ripka's Equipment Repair
Carlos Quintero
david@ripkasequiprepair.com
Vista, CA
760-716-8266
Weldworx Solutions
Warren Jones & Nathan Simpson
warren@weldworx.org
Darby, MT
406-471-7646
“With today’s extra long reaching booms and the higher strength steels being used, the correct repair
procedures and standards must be followed to insure the structural integrity of the repair.”
– Jeff Popa

Current Revisions of SCHWING
Inspection Reports
Structural/Operational/Repair Request Form
Structural Periodic Inspection Report